Notification Appliance CircuitNAC

The circuit that powers horns, strobes, speakers and bells. Normally held at reverse polarity for supervision and switched to alarm polarity (or driven with audio) when the panel goes into alarm. Sized by voltage drop and total appliance current.

NFPA 72: Chapter 12, Chapter 18 (Notification Appliances)