Permanent tabs, highlighter-only marking and the exact pages worth finding fast. Pick your book, tick off each tab as you place it, then print the checklist for your desk.
Pearson VUE testing-center book rules (NICET)
1
Tabs must be permanently affixed. Use adhesive plastic or paper tabs. Removable Post-it notes and flags are prohibited and will be confiscated at check-in.
2
Highlight and underline only. Highlighting and underlining in ink are permitted. Writing notes, formulas or definitions in the margins is strictly prohibited — a marked-up book can be rejected.
3
No loose paper. No loose papers, study guides, printed tables or unbound printouts are allowed in the testing room. Everything you need must be bound inside the codebook.
Rules change — confirm the current NICET/Pearson VUE candidate policy before test day. Books with notes or removable flags can be refused at check-in.
NFPA 72-2022 National Fire Alarm and Signaling Code
Elevator Phase I recall, shunt trip heat detectors, HVAC shutdown, door release.
Sub-tab / find these
▸21.3 Elevator Phase I emergency recall (lobby, hoistway, machine room detectors)
▸21.4.2 Shunt-trip heat detector within 2 ft of each sprinkler
▸21.7 HVAC systems
▸21.8 Door release service / 21.9 Electrically locked doors
Highlight (ink only — no margin notes)
▮21.3.x alternate recall level logic
Ch 23
Protected Premises Systems
Level II+
Positive alarm sequence timing, alarm verification, zoning, and FACU interconnection.
Sub-tab / find these
▸23.8.1.3 Positive alarm sequence: 15 s acknowledge, 180 s investigate
▸23.8.5.4.1 Alarm verification ≤ 60 s
▸23.8.2 Interconnected FACUs
Highlight (ink only — no margin notes)
▮23.8.1.3 items (1)–(4)
Ch 24
Emergency Communications (Voice)
Level III–IV
In-building fire EVACS, survivability levels for partial evacuation, intelligibility, two-way systems.
Sub-tab / find these
▸24.3.14.4.1 Pathway survivability Level 2/3 for partial evacuation
▸24.4.2 In-building fire EVACS
▸24.5.1 Two-way in-building wired ECS (area of refuge)
Highlight (ink only — no margin notes)
▮24.4.2.x message priority and live voice override
Ch 26
Supervising Stations
Level II+
Central (26.3) vs proprietary (26.4) vs remote (26.5); communication paths and runner service.
Sub-tab / find these
▸26.3 Central station service
▸26.4 Proprietary supervising station
▸26.5 Remote supervising station
▸26.6 Communications methods
Highlight (ink only — no margin notes)
▮26.3 indication of central station service (placard) — underline the required marking
Annex A/B
Explanatory Material & Engineering Guide
Level II+
A.17.7.3.2.4 explains beam spacing figures; Annex B gives the detector design math for Level III–IV.
Sub-tab / find these
▸Annex A explanatory notes keyed to each section (A.x.x.x)
▸Annex B Engineering Guide for Automatic Fire Detector Spacing
Highlight (ink only — no margin notes)
▮A.18.4.4 ambient sound level table