Isolator Module

An SLC device that opens the loop on either side of a short circuit so the rest of the addressable loop keeps working. Required to meet Class X and often used to limit the devices lost to one fault.

NFPA 72: 12.3, 23.6.1

Section numbers vary by edition — confirm in the edition your AHJ has adopted.

Read more in these guides

Related terms

Fire Alarm Blueprint Trainer provides educational guidance only. It does not replace professional engineering, licensed electrical work, approved fire alarm design, manufacturer installation instructions, applicable codes, or AHJ review.